Molecular Spectroscopy

Welcome to your Molecular Spectroscopy

The basic principle of fluorimetry is based on:

The tungsten lamp is used as a light source in:

In fluorimetry, the excitation monochromator selects:

IR spectroscopy is based on:

Fluorimetry is more sensitive than UV-Vis spectroscopy because:

The pharmaceuitcal applications of UV-Visible spectroscopy include:

The pharmaceutical applications of fluorimetry include:

The Beer-Lambert Law is expressed as:

In Beer-Lambert Law, ε represents:

A hyperchromic effect refers to:

The deuterium lamp is used as a light source in:

The detector commonly used in UV-Visible spectrophotometers is:

Cuvettes used for visible measurements can be made of:

A bathochromic shift refers to:

A chromophore is a functional group that:

The solvent used in UV-Visible spectroscopy should be:

A hypochromic effect refers to:

The light source used in fluorescence spectrophotometers is:

In Beer-Lambert Law, b represents:

In Beer-Lambert Law, c represents:

Quenching in fluorescence refers to:

UV-Visible spectroscopy involves the measurement of absorption of:

A double beam UV-Visible spectrophotometer has:

A hypsochromic shift refers to:

The maximum absorption wavelength (λmax) is:

The wavelength range of IR radiation is approximately:

Qualitative analysis in UV-Vis spectroscopy involves:

The Stokes shift in fluorescence refers to:

The functional group region of an IR spectrum is:

The wavelength range of UV radiation is approximately:

The detector used in fluorescence spectrophotometers is:

The IR spectrum is typically presented as:

The pharmaceutical applications of IR spectroscopy include:

The hydroxyl group (O-H) typically absorbs in the range of:

Fluorescence is the emission of light by a molecule after:

Cuvettes used for UV measurements are made of:

The fingerprint region of an IR spectrum is:

The carbonyl group (C=O) typically absorbs in the range of:

In fluorimetry, the emission monochromator selects:

The UV-Visible spectrum shows absorbance vs:

The wave number (cm⁻¹) is:

In a single beam spectrophotometer, the reference measurement is done:

FTIR stands for:

Quantitative analysis in UV-Vis spectroscopy involves:

The time between absorption and emission in fluorescence is approximately:

The time between absorption and emission in phosphorescence is:

The emitted wavelength in fluorescence is:

Phosphorescence is the emission of light after:

The wavelength range of visible radiation is approximately:

Fluorimetry can be used for analysis of: